Mersen AJT60
78200196238
600V 60A Class J Time-Delay Fuse Mersen AJT60
|
|
Mersen AJT60 |
78200196238 |
Manufacturer: FRZ
|
Mersen A4J - Class J - Fast-Acting Fuse
Specs:
Volts (VAC) 600
Volts (VDC) 500
Ampere (A) 60
I.R. AC (kA) 200
I.R DC (kA) 100
IR Other (kA) 300kA 600V AC Self Certified (UL Witnessed), 300kA 600V AC Self Certified (UL Witnessed)
Class Class J
Size per Standard Class J
Speed / Characteristic Time-delay
Mounting Clip
Connection Terminal Type Ferrule, Blade
Body Style Cylindrical, Rejection
Body Material GMG
Materials Contact Tin-plated Copper, Silver-Plated Copper, Brass
Minimum Operating & Storage Temp °C -25
Ratings:
UL Listed to Standard 248-8, File E2137, DC Listed to UL Standard 248, CSA Certified to Standard C22.2, No. 248.8,
IEC 269-2-1
Description:
Amp-Trap 2000 time-delay AJT fuses provide IEC Type "2" (No Damage) protection to main, feeder, and branch-circuits, for all types of loads - yet, they require only half the mounting space needed for 600V UL Class RK fuses. Time-delay characteristics handle motor in-rush currents without nuisance trips. Its current-limiting ability and wide range of ratings provide excellent overcurrent protection for all your applications. An optional mechanical blown fuse indicator and Microswitch is available on blade-type (70 to 600A) fuses for visual and/or remote blown fuse indication. Solid-state SmartSpot indicator, Time-delay for motor starting and transformer inrush, 300kA interrupting rating, self-certified (UL witnessed), Extremely current-limiting for low peak let-thru current, Most current-limiting UL class fuse, Small footprint requires less mounting space and allows smaller, more economical fuse blocks, Easy 2-to-1 selectivity for prevention of nuisance shutdowns, Unique Class J dimensions prevent replacement errors, High-visibility orange label gives instant recognition, Metal embossed date and catalog number for traceability and lasting identification,
Fiberglass body provides dimensional stability in harsh industrial settings, High-grade silica filler ensures fast arc quenching. Application Motor Circuits, Mains,
Feeders, Branch Circuits, Lighting, Heaters, Transformers, Control Panels, Circuit Breaker Back-up,
Bus Duct, Load Centers. Mersen (also known as Ferraz Shawmut and Gould Fuses).
Part-Drawing
Performance Data
Performance Data-Peak Let Thru
Data Sheet
Application Guidelines
Application Guidelines
Brochure-Fuses
Fact Sheet
Reference-Coordination Guide-Allen Bradley
Reference-Coordination Guide-Cutler Hammer
Reference-Coordination Guide-Square D
Reference-Coordination Guide-General Electric
|
|